All programming is performed from a display telephone connected to extension 101. To enter programming mode move the switch on the back of the phone to Program and press *#1234.

  • 000--- Date and Time Setting
  • 001--- System Speed Dial Entry
  • 002--- System Password
  • 003--- DSS Console Port Assignment
  • 004--- Paired Telephone Assignment for DSS Console
  • 005--- One-Touch transfer Using a DSS Button
  • 006--- Time (D/N/L) Service Changing Mode
  • 007--- Time (D/N/L) Service Start Time
  • 008--- Operator Assignment
  • 009--- Extension Number Assignment
  • 010--- LCD Time Display Selection
  • 011--- System speed dial name setting (-4+)
  • 100--- Hunting Group Set
  • 101--- Station Hunting Type
  • 102--- Voice Mail Port
  • 103--- DTMF Integration
  • 104--- Hold Mode Selection
  • 105--- Conference Tone
  • 106--- External Paging Access Tone
  • 107--- DTMF Receiver Check
  • 108--- Flash Mode for a Station Locked Ext
  • 109--- CO Indicator Assignment
  • 110--- Flash Key Mode
  • 111--- Hold Music Selection
  • 112--- DSS Console Indication Mode
  • 113--- Automatic Redial Repeat (Up to –2 only)
  • 114--- Automatic Redial Interval Time (Up to –2 only)
  • 115--- Ext Ringing Pattern Selection
  • 117--- Call Pickup Tone
  • 118--- Pulse Restriction
  • 119--- Redialing After Pulse to Tone Conversion
  • 125--- Toll Restriction Check for * and #
  • 130--- Voice Mail 1 APT Port for KX-TVS50 (-1+)
  • 131--- Voice Mail 2 APT Port for KX-TVS50 (-1+)
  • 140--- Ring Mode (–1 –2 only)
  • 200--- Hold Recall Time
  • 201--- Transfer Recall Time
  • 202--- Call Forwarding Start Time
  • 203--- Pickup Dial Delay Time
  • 204--- Call Duration Count Start Time
  • 205--- Outside to Outside ( CO to CO ) Line Duration Time Limit
  • 206--- Dialing Start Time
  • 208--- Interdigit Time
  • 211--- No Dial Disconnect
  • 300--- Carrier Code Assignment
  • 301--- Toll Restriction --- System Speed Dial
  • 302-305--- Toll Restriction --- Class 2 --- 5 Denied Codes
  • 306--- Toll Restriction --- Exception Codes
  • 309--- Emergency Dial Number Set
  • 310--- Account Codes
  • 311--- Automatic Pause Insertion Codes
  • 312--- Toll Restriction- Station Lock Boundary Class
  • 400--- Outside CO Line Connection Assignment
  • 401--- Dial Mode
  • 402--- Pulse Speed Selection
  • 403--- Host PBX Access Codes
  • 404--- Outside CO Line Group Assignment
  • 405-407--- Flexible Outward Dialing Assignment D/N/L
  • 408-410--- Flexible Ringing Assignment D/N/L
  • 411-413--- Delayed Ringing Assignment D/N/L
  • 414-416--- Outside CO Line Mode D/N/L
  • 417--- Pause Time
  • 418--- Flash Time
  • 419--- Automatic Designated Outside CO Line Access
  • 420--- Calling Party Control CPC Signal
  • 421--- CPC Detection for Outgoing Calls
  • 422--- Disconnect Time
  • 423--- Outside CO Line Ringing Pattern Selection
  • 500--- DISA Incoming Dialing Mode Selection
  • 501--- DISA Built-in AA
  • 502--- OGM Mode Selection
  • 503--- Fax Connection
  • 504--- DISA Delayed Answer Time
  • 505--- DISA Waiting Time After OGM
  • 506--- DISA Busy Mode
  • 507--- DISA Intercept Mode
  • 508--- DISA Ringing Time Before Intercept
  • 509--- DISA Ringing Time After Intercept
  • 510--- DISA No Dial Mode
  • 511--- DISA Security Type
  • 512--- DISA Security Codes
  • 513--- Cyclic Tone Detection
  • 514--- Fax Tone Detection
  • 515--- Intercept Time for Internal DISA
  • 517--- DISA AA Wait Time (-3 +)
  • 516--- DISA Incoming Assignment
  • 518--- DISA Tone Selection After Security Code
  • 530--- DISA Security Codes Digits Selection (-3+)
  • 600--- Ext Group Assignment
  • 601-603--- TRS-Class of Service Assignment D/N/L
  • 604--- Ext Name Setting
  • 605--- Account Code Entry Mode
  • 606--- Call Transfer to Outside Line
  • 607--- Call FWD to an Outside Line
  • 608--- Executive Busy Override
  • 609--- DND Override
  • 610--- Paralleled Telephone Connection
  • 611--- Telephone Answering Machine Ext
  • 612--- Room Monitor Assignment
  • 617--- Wireless PT port Assignment
  • 618--- MWL For Other Ext (-3+)
  • 620--- Live Call Screening Mode Assignment (-2+)
  • 700-702--- Doorphone Ringing Assignment D/N/L
  • 703-705--- Door Opener Assignment D/N/L
  • 706--- Doorphone Ringing/Tone Pattern D/N/L
  • 707--- Doorphone Access Tone Selection
  • 708--- Doorphone Ringing Time
  • 709--- Door Opener Time
  • 710--- Doorphone Ring/Chime Selection (-3 Y591B+)
  • 711--- Doorphone Chime Assignment (-3 Y591B+)
  • 712--- Doorphone Chime Pattern Selection (-3 Y591B+)
  • 800--- SMDR RS-232C Communication Parameters
  • 801--- SMDR Parameter
  • 802--- Incoming/Outgoing Call Selection For Printing
  • 803--- Secret Speed Dialing/One-Touch Dialing Printing
  • 804--- System Data Dump
  • 805--- SMDR Account Code Selection
  • 900--- Caller ID Assignment
  • 901--- Caller ID Area Code Assignment
  • 902--- Caller ID Modification for Local Calls
  • 903--- Caller ID Modification for Long Distance Calls
  • 904--- Caller ID Log Priority Selection
  • 906--- Caller ID SMDR Format
  • 907--- Caller ID SMDR Printout Selection (-3+)
  • 908--- CID Call Waiting Time (-3+)
  • 909--- Common Area Call Log Check Assignment (-3+)
  • 968--- Kx-T77xx Incoming lamp control (-4+)
  • 963--- Call Forwarding Selection (-1+)
  • 998--- ROM Version
  • 999--- System Data Clear

 
Advanced Search
Wiremold Legrand 2400 Series Steel Raceway Device Box
Contact Us
Compact Plug-In Outlet Center with Six Outlets and Lighted Switch

 
  
top
WiremoldProducts.com, an online retailer of Legrand products, is a leading provider of raceways and rack mount outlets. We specialize in surface raceways, rack mount outlets and accessories. All orders, small or large, are welcomed with no minimum order requirements.
GSA, Visa, MasterCard, and American Express Credit Cards Accepted
This site is not affiliated with Legrand North America, Inc. or any of its subsidiaries. Legrand North America, Inc. ("LNA") trademarks include the logos of all LNA's companies and other designs and logos owned and used by LNA, as well as LNA product and service names. . As used herein, "LNA" includes all affiliated companies, including Cablofil Inc., On-Q Inc., Ortronics, Inc., Legrand Home Systems, Inc. (formerly OnQ Inc. and Vantage Controls, Inc.), Legrand Canada, Inc., The Watt Stopper, Inc., and The Wiremold Company. All logos displayed on this page are registered trademarks with their respective organizations.
Copyright © 1997 - 2024 TWAcomm.com, Inc. All rights reserved. - 4/16/2024 7:40:25 AM - v.8.0.16